44
The next decompression stop is at 24 metres for 1 minute.
If the diver rises above this depth then the two digits flash in
red
.
The decompression is cleared and the diver can ascend to the surface
Shows the hours and minutes since the end of your last dive. Above 4
days, the surface interval is displayed in days.
• Decompression stop at 24 metres for 1 minute
Note:
The last decompression stop can be set to either 3 of 6 metres.
• The “Center Row” shows the current PPO2 measurement values from the oxygen sensors.
The controller constantly displays the
current PPO2 measurement values from
the three oxygen sensors. A deselected
sensor is displayed in
yellow
and is not
taken into account in the calculation of
the average PPO2. PPO2 values below
0.4 or above 1.6 flash in
red
.
Battery “OK”
The yellow
battery warning appears if the battery voltage falls below 3.28V for 30
seconds (SAFT 14500). The battery should be replaced as quickly as possible.
The battery warning flashes
red
, if the voltage is below 3.15V. If the battery volt-
agedrops to less than 3.2V for 30 seconds (SAFT 14500) then an additional
”LOW
BATTERY INT”
error warning appears in the display. In this case the battery voltage
is extremely low and the battery must be replaced immediately!
• A battery warning – The default behavior is that the battery icon is shown at the surface but disap-
pears when diving. If low or critical than the battery icon will appear while diving.