JJ-CCR ApS 2017
www.JJ-CCR.com
2017 JJ-CCR ApS – 2.00 / Revision 06
85
Info Screens
Description
CC mode
BO mode
DilPO2:
Displays the current PPO2 of the diluent. If the value is lower
than 19 or higher than 1.65 then it flashes
red
.
CNS:
Shows the current CNS saturation as a percentage: From 100% or
above, the value flashes
red
. The CNS saturation is calculated constant-
ly, also at the surface and even if the computer is switched off.
SP:
Displays the current active setpoint. The setpoint
.19
is displayed in
yellow
. All other setpoints in white
.
AvgPO2:
Indicates the average PO2 of the breathing gas. The basis for
calculation is the average of the measured values of all sensors which
have not been excluded. If the value is lower than .40 or higher than
1.60 then it flashes
red
.
CNS:
Shows the current CNS saturation as a percentage: From 100% or
above, the value flashes
red
. The CNS saturation is calculated constant-
ly, also at the surface and even if the computer is switched off.
AvgPO2 (BO Mode):
Indicates the average PO2 of the breathing gas. If
the value is lower than .19 or higher than 1.65 then it flashes
red
.
CC and BO mode
Indicates the current millivolts of the connected O2 sensors.
CC und BO mode
MAX:
Indicates the maximum depth of the current dive. When not in
dive mode, the maximum depth of the last dive is displayed here.
AVG:
Indicates the average depth of the current dive. When not in dive
mode, the average depth of the last dive is displayed here.
AvgATM:
AvgATM:
Indicates the average depth of the current dive in
absolute pressure (= 1.0 ATM equals sea level).
6.22 Info Screens
Starting from the main screen, the right button steps through the info screens. Info screens time-out after
10 seconds, returning to the main screen. Pressing the left button will also return to the main screen.
When enabled the compass is shown as the first info screen. Unlike the regular info screens, the compass
never times out back to the main screen.