JJ-CCR ApS 2017
www.JJ-CCR.com
2017 JJ-CCR ApS – 2.00 / Revision 06
35
5.3.9 Advanced Options
There are two options that can be set by the user. 1) Choosing the PPO2 blink pattern. 2) Flipping the
orientation to the other side of the rebreather mouthpiece.
•
Flipping the orientation to the other side of the rebreather mouthpiece makes no sense with the JJ-CCR
rebreather, as the HUD holder on the DSV is on the right side. This function is only useable, when some-
body connects another DSV oder BOV to the JJ-CCR which allows to attach the HUD to the left side.
1. Turn the HUD on by pressing the button once.
2. Press once to enter 1st command column (TURN-OFF)
3. Press again to advance to 2nd command column (CALIBRATE).
4. Press again to advance to 3rd command column (MENU).
5. Hold for 3 seconds to enter the advanced options menu
6. Once in the advanced options menu, the 1st column will alternately blink the top-red and bottom-
red LEDs.
7. Each press advances the option column by one position.
8. Select the option by holding for 3 seconds while the option column is blinking
9. An option column will time-out, returning to the regular PPO2 display after 20 seconds of inactivity.
Also, an additioinal press when on the last option column will return to the regular PPO2 display.
Smithers Code
Color Blind Code
Flip Orientation