Alarm and error messages
Description
Gas PPO2 unsafe
The gas will display in flashing red when its PPO2 is outside of a safe
breathing range (i.e. below the min PPO2 or above the max PPO2 set-
ting). In closed circuit (CC) mode, this warning refers to the diluent only.
The breathing loop PPO2 may be in a safe range, but if the diluent is
unsafe to breathe directly then the gas will be red. Note that other warn-
ings exist to warn when the breathing loop is outside of a safe range.
High PPO2
The high ”
HIGH PPO2
” alarm message appears if a PPO2 of 1.60 has
been exceeded for more than 10 seconds. With the first warning it is
necessary to confirm this by pressing the right button. If, during the
same dive, the PPO2 should once again be too high then it is not neces-
sary to confirm this again (see second image). The PPO2 values and
the ”
High PPO2
” warning flash in
red
.