6.20.1
Mode Setup
6.20.2
Salinity
(Mode Setup)
The first submenu of the system setup is ”Mode Setup”. The options
“Low SP” and “High SP” are identical to those in the dive setup menu.
•
The options “Mode” and “PPO2 Mode” can’t be edited because they are
fixed and appear grayed-out.
By pressing the right button ”Edit” the
user accesses the edit mode for the low
setpoint. In order to change the value it is
necessary to press the left button ”Chan-
ge” until the desired value is displayed
(possible values are 0.4 to 1.5). By pressing
the right button ”Save” the current value
is saved and the user switches to the next
entry. The current entry is marked with a
”
u
“.
6.20.3
Low Setpoint
(Mode Setup)
Water type (salinity) affects how the measured pressure is converted to
depth.
Setting
Description
EN13319
The EN13319 value is between Fresh and Salt. It is
from the European CE standard for dive computers,
and is the controller’s default value
Fresh
Fresh water
Salt
Salt water
•
Fresh and Salt water differ by about 3%. Salt water, being denser, will display a shallower depth for the
same measured pressure versus the Fresh water setting.
•
The setting only has an impact for the displayed depth. It has no impact on the decompression
calculation.