PAGE 51 of 89
EB0162 Rev 00
TIP:
Circumstance may arise when only one person is available for
placement of the crawler on an inspection surface. With the system
power off, it is possible to place the crawler on the inspection/removal
mat and manually push the crawler off the mat and onto the inspection
surface.
6.2.2.3 Detector Setup
1.
Attach the detector to the detector bracket
(see “Attaching Detector to the
Detector Bracket” on page 29)
.
2.
Mount the detector
bracket
(Fig. 102)
to the
crawler
(see “Mounting
Detector Bracket to
Crawler” on page 30)
.
3.
Angle and align the
detector bracket as
required
(see “Positioning
the Detector” on page
32)
.
6.2.2.4 Crawler Position
1.
Use the handheld
controller to drive the crawler to the top dead centre of the pipe before
beginning the 1 Axis Scan Setup
(see “1 Axis Scan Mode” on page 56)
.
Fig. 102 - Mount detector bracket to the magnetic crawler
Fig. 103 - Prepared SKOOT • X magnetic system