10 Connection Diagrams
90
Jetter AG
Key to wiring diagrams:
1
Line filter (optional) (refer to “Line filter" on page 39)
2
Mains protection (refer to “Overload Protection" on page 38)
3
Motor
4
Motor holding brake (option)
5
– Connecting without the option -S1 (Safe Torque Off): The
input for enable is connected in single-channel mode.
– Connecting with the option -S1 (Safe Torque Off): Enable1
and Enable2 are connected in dual-channel mode.
6
The motor holding brake is controlled via an internal
semiconductor-switch. A free-wheeling diode has been
integrated.
7
To use initiators for end position and reference inputs, a 24 V
power supply unit and a 0 V ground have been made available
as terminals.
8
Position transducer (resolver or HIPERFACE encoder)
9
Motor-temperature protection (see “Thermal sensor integrated
in the motor" on page 43)
10
At using the option -JC24x, the Bus-In connector X18 must not
be applied, as the system bus is connected with the JM-D203
internally.
Summary of Contents for JetMove D203
Page 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 92: ...11 Option S1 STO 92 Jetter AG...
Page 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Page 134: ...Appendices 134 Jetter AG...