2 Installation of the JetMove D203
26
Jetter AG
2.3
Electrical Installation
Check for correct motor and servo amplifier assignment.
Compare rated voltage and continuous rated current of servo amplifier
and motor.
The motor must be isolated against voltages of DC 500 V min.; please
also refer to “Compatible Synchronous Servo Motors" on page 43.
Connect the JetMoveD203 according to the connection wiring diagram
shown in chapter 10 "Connection Diagrams", page 87.
Especially check the power lines for appropriate protection, see
“Overload Protection" on page 38.
We do not recommend to fuse the motor cables.
Select the cables according to standards.
Verify that all earthing cables are connected (double earthing).
To connect resolvers or power units you can use prefabricated cables
available from Jetter or opt for self-made cables. Please refer to
chapter 7 "Description of Connections", page 49.
To ensure that installation is carried out in conformance with EMC
regulations, follow the instructions below:
– If possible, do not connect the controller cable together with the
power supply and motor cable;
– Connect the position transducer;
– Use shielded terminals or EMC-compliant connectors;
– Connect the holding brake, if available, and connect shields at both
ends of the cables;
– Connect the motor leads according to fig. 3, page 22.
Please also follow the instructions in chapter 1.4 "Instructions on EMC",
page 20.
Summary of Contents for JetMove D203
Page 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 92: ...11 Option S1 STO 92 Jetter AG...
Page 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Page 134: ...Appendices 134 Jetter AG...