JetMove D203
1.3 Residual Dangers
Jetter AG
17
1.3
Residual Dangers
1.3.1
Hazards during Operation
DANGER
Hazard caused by high operating voltage!
Extremely hazardous voltages of up to DC 500 V may occur!
Such voltages may result in muscle cramps, burns, unconsciousness, respiratory
standstill, or death.
During operation, keep all covers and electric cabinet doors closed.
Do not remove the cover.
Do not disconnect electrical connections of the JetMove D203 while they are
energized.
DANGER
Do not touch the terminals X1, X74 and X84 while the servo amplifier is
running
.
The terminal designations mean:
X1:
AC 230 V voltage supply
X74, X84:
DC motor voltage up to 500 V
CAUTION
Caution! Hot surfaces!
During operation, the surfaces, respectively the heat sinks of the JetMove D203
can heat up. The left sidewall can reach temperatures of up to 80 ¬×C.
Do not touch the left sidewall during operation and after switching off
while the device is still cooling down.
Make sure that no temperature-sensitive parts are in contact with or
attached to the servo amplifier JetMove D203.
Summary of Contents for JetMove D203
Page 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 92: ...11 Option S1 STO 92 Jetter AG...
Page 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Page 134: ...Appendices 134 Jetter AG...