JetMove D203
Jetter AG
33
Operating Parameters
EMI - Immunity to Interference
Enclosure
Parameter(s)
Value(s)
Reference
standard
ESD
Discharge through air:
Test peak voltage 8 kV
Contact discharge:
Test peak voltage 4 kV
Criterion B
(Electromagnetic environment in
industrial plants)
DIN EN 61800-3
DIN EN 61000-4-2
RF Field
amplitude-modulated
Frequency band 80 ...1000 MHz;
test field strength 10 V/m
AM 80 % at 1 kHz
Criterion A
(Electromagnetic environment in
industrial plants)
DIN EN 61800-3
DIN EN 61000-4-3
Operating Parameters
EMI - Immunity to Interference
Power Connections
Parameter(s)
Value(s)
Reference
standard
Burst (fast transients)
Test voltage 2 kV
Repetition frequency 5 kHz
Criterion B
(Electromagnetic environment in
industrial plants)
DIN EN 61800-3
DIN EN 61000-4-4
Impulse voltages
tr/th 1.2/50 µs, 8/20 µs
1 kV (phase to phase)
2 kV (phase to ground)
Criterion B
(Electromagnetic environment in
industrial plants)
DIN EN 61800-3
DIN EN 61000-4-5
Guided radio
disturbances
Frequency 0.15 ... 80 MHz
Test voltage 10 V
AM 80 % at 1 kHz
Criterion A
(Electromagnetic environment in
industrial plants)
DIN EN 61800-3
DIN EN 61000-4-6
Summary of Contents for JetMove D203
Page 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 92: ...11 Option S1 STO 92 Jetter AG...
Page 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Page 134: ...Appendices 134 Jetter AG...