7 Description of Connections
64
Jetter AG
Fig. 14: Sin-cos encoder connection of +5 V supply voltage
Fig. 15: Sin-cos encoder connection with a feedback control of the supply
voltage
INFO 1.1
Supply v5 V at the JetMove D203:
If the sense wires are not connected, the supply voltage of +5 V is issued at the
JetMove D203. Due to performance degradation, a lower voltage might be
supplied to the encoder.
Sin-Cos Encoder
JetMove D203
X71 / X81:
15-pin
SUB-D
connector
Sense+
Sense -
+ 5...8.5V
0 V
Sin+
Cos+
Index+
Sin-
Cos-
Index-
6
14
5
13
1
2
3
9
10
11
+ 5...8.5V
0 V
Sin+
Cos+
Index+
Sin-
Cos-
Index-
INFO 1.2
Supply v5 V at the encoder:
With the help of the sense connections, the supply voltage can be controlled in a
way that +5 V are supplied to the encoder. Wiring should be carried out as follows:
Sin-Cos-Encoder
JetMove D203
X71 / X81:
15-Pin
SUB-D Connector
Sense+
+ 5V
0 V
Sin+
Cos+
Index+
Sin-
Cos-
Index-
Sense -
+ 5
0V
Sin+
Cos+
Index+
Sin-
Cos-
Index-
5 V
6
5
13
14
1
2
3
9
10
11