JetMove D203-JC24X
12.7 Status LEDs, Mode Selector
Jetter AG
111
12.7.2 The mode selector
When the integrated controller is powered-up, the position of the mode selector is
read out.
Fig. 32: Settings of the mode selector S11
By means of the built-in mode selector, the starting behavior of the integrated
controller can be influenced.
Start-Up Process
Once the start-up procedure has been completed, the position of the mode selector
has no longer influence on the controller functions. The current position of the mode
selector can be scanned in register 10181.
Mode Selector
Position
Description
LOAD
The boot process proceeds as far as to
the boot loader
STOP
The application program is not started
RUN
The application program is started