JetMove D203
5.1 Electrical Specification
Jetter AG
39
Line filter
A line filter ensuring unlimited EMC
in
residential environment to DIN EN 61800-3
is needed. The following filters can be
applied with input circuits:
– NEFB 10332 with I
r
= 16 A
– NEFB 10333 with I
r
= 25 A
– NEFB 10334 with I
r
= 36 A
Internal ballast resistor
• Resistor: typically 120
• Rated power: 60 W
• Energy dissipation: 800 Ws (Joule)
The energy dissipation is dependent on
the actual enclosure temperature and
the footprint.
See “INFO 3” on page 41.
See “Typical power dissipation of the
ballast resistor” on page 42.
Residual voltage
To avoid hazard of electrical shock wait at
least 5 minute after switching-off the digital
servo amplifier before attempting to pull out
the plug or remove this unit (refer to
Page 19).
Leakage current
> 3.5 mA
See “Danger resulting from electric
shock!” on page 42.
Voltage supply of processor logics
(demands on power supply
module)
• DC 24 V (20 ... 28.8 V)
≤
1.3 A
• For the option -JC24x, additionally 0.35
A max. are needed. For using a display
at X12, additionally 0.75 A max. are
needed.
• The voltage output of the power supply
unit must comply with the SELV or PELV
type.
Inrush current limitation of the
processor logics
The JM-D203 is equipped with an internal
4700 µF capacitors for buffering. The inrush
current is not limited.
Digital inputs
– Enable1/2,
– Reference switch (REF),
– Positive limit switch (Limit+),
– Negative limit switch (Limit-)
– Input (Inp)
• DC 20 V ... 28.8 V related to the ground
potential of the processor logics
• Input current of 7.5 mA max. each
• For the option -S1 (Safe Torque Off), the
input current is 50 mA max. per input
• Refer to chapter 7.7 "Digital Inputs, Logic
Electrical Specification
Ω
Summary of Contents for JetMove D203
Page 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 92: ...11 Option S1 STO 92 Jetter AG...
Page 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Page 134: ...Appendices 134 Jetter AG...