Jetter AG
Registers - Overview | 9
SW function JCF-SV1
Register
range
Description
Initializing the JCF-SV1 SW function
600000
Status register
600001
Activation of instances
600002
Call interval
600003
Cycle time of all instances
600004 …
600009
Reserve
Configuring the JCF-SV1 SW function for indi-
vidual axes
600010 …
600029
Axis 1
600010
Source register number of the
actual position
600011
Target register number of the
manipulated variable
600012
Input number: Negative HW limit
switch
600013
Input number: Positive HW limit
switch
600014
Input number: Reference switch
600015
Output number: Dig. neg. direction
preset
600016
Output number: Dig. pos. direction
preset
600017
Output number:
Dig. ENABLE for the amplifier
600018 …
600029
Reserve
600030 …
600049
Axis 2
600030
Source register number of the ac-
tual position
600031
Target register number of the ma-
nipulated variable
…
…
600038 …
600049
Reserve
600050 …
600069
Axis 3
→ see axis 1
600070 …
600089
Axis 4
→ see axis 1
600090 …
600109
Axis 5
→ see axis 1
600110 …
600129
Axis 6
→ see axis 1
Register
range
Description
600130 …
600149
Axis 7
→ see axis 1
600150 …
600169
Axis 8
→ see axis 1
600170 …
600189
Axis 8
→ see axis 1
600190 …
600209
Axis 10
→ see axis 1
600210 …
600229
Axis 11
→ see axis 1
600230 …
600249
Axis 12
→ see axis 1
600250 …
600269
Axis 13
→ see axis 1
600270 …
600289
Axis 14
→ see axis 1
600290 …
600309
Axis 15
→ see axis 1
600310 …
600329
Axis 16
→ see axis 1
Operation of individual axes
6yyzzz
6= prefix
yy = axis number 01 … 16
zzz = module register number 000 … 999
601000 …
601999
Axis 1
602000 …
602999
Axis 2
…
…
616000 …
616999
Axis 16
Application registers
Registers
Description
1000000 ...
1059999
32-bit integer or floating point num-
ber (non-volatile)
1000000 ...
1119999
32-bit integer or floating point num-
ber (non-volatile), with option -R
User Manual – JetControl 365MC
128 / 148