Jetter AG
Programming | 8
User Manual – JetControl 365MC
92 / 148
1
Controller
2
Ethernet switch
3
Up to 64 Ethernet bus nodes per controller
Up to 16 JX3 I/O modules per Ethernet bus node
Definition - Global
Node Number
The Global Node Number (GNN) is an ID number used to identify Jetter devices
(e.g. controllers, bus nodes) within an Ethernet network:
■
Within a network, the GNN must be unambiguous for each Jetter device.
■
The JetSym Hardware Manager automatically assigns the GNN during config-
uration.
■
The value range of the GNN within a project is 000 ... 199.
■
The controller has always got GNN 000.
Register numbering system
The register numbers consist of a prefix, the GNN, the module position within the
system and the module-specific register number.
1
NNN
XX
ZZZZ
Fig. 22:
Example:
Register numbers
Digits
Description
Value range
1
Prefix
NNN
Bus node ID, GNN
001 … 199
XX
Position of the module within the
station
02 … 17
ZZZZ
Module register number
0000 … 9999
I/O numbering system
The inputs or outputs of the module are directly accessed via I/O numbers. The I/
O numbers consist of prefix 1, the GNN, prefix 2, the module position in the sys-
tem and the module-specific I/O number.
1
NNN
01
XX
ZZ
Fig. 23:
Example:
I/O numbers
Digits
Description
Value range
1
Prefix 1
NNN
Bus node ID, GNN
001 … 199
01
Prefix 2
XX
Position of the module within the
station
02 … 17
ZZ
Module-specific I/O number
01 … 16
INFO
Further information
Further information on this topic can be found in the Application-oriented Manual
Jetter Ethernet System Bus