Test Report No.: No.: 17706687 001
Part II of II
Page 28 of 63
EN 61029-1:2009+A11
Clause
Requirement
Test
Result - Remark
Verdict
appreciable extent and that there is no trace of
water on insulation for which creepage distances
are specified in 27.1.
15
INSULATION RESISTANCE AND ELECTRIC STRENGTH TEST
P
15.1
Adequate insulation resistance and electric
strength
See below
P
Test conditions
Cold tool, after humidity
treatment.
P
15.2
Insulation resistance
See below
P
Limits for insulation resistance
See below
P
Measurement of insulation resistance .....................: Limit:
TS-315D:
Live part - Tool enclosure:
7M
.
Live part - Switch button: 7M
Live part - Saw blade: 7M
Inner and outer surface of
switch box: 5M
All measured values exceed
100 M
.
P
15.3
Electric strength
See below
P
Electric strength test .................................................: The electric strength test is
carried out at the followed
locations:
TS-315D:
L/N- Tool enclosure: 3750V.
L/N- Switch button: 3750V.
L/N- Saw blade: 3750V.
Inner and outer surface of
switch box: 2500V
Series point to motor
enclosure: (1000+2x282)V
TS-315G:
L1/L2/L3 - Tool enclosure:
3750V
L1/L2/L3 - Switch button:
3750V
L1/L2/L3 - Saw blade: 3750V
Inner and outer surface of
switch box: 2500V
P
16
ENDURANCE TEST
P
16.1
Tools operating in extended normal use
See below
P
Summary of Contents for JTS-315LA
Page 2: ......
Page 3: ...8 JPW s CE declaration of conformity with latest directives and EN standards...
Page 4: ...9 CE certificates...
Page 5: ......
Page 6: ......
Page 17: ...Appendix A A1 A2 A3 A4...
Page 19: ...Parts Breakdown for JTS 315LA Table Saw...
Page 30: ......
Page 41: ......
Page 124: ...Circular Saw Bench...