Test Report No.: No.: 17706687 001
Part II of II
Page 46 of 63
EN 61029-1:2009+A11
Clause
Requirement
Test
Result - Remark
Verdict
Distance through insulation
The distance through capacitor box is 2mm.
27
TABLE: clearance and creepage distance measurements for TS-315G
P
clearance cl and creepage
distance dcr at/of:
U r.m.s.
(V)
required cl
(mm)
cl (mm)
required dcr
(mm)
Dcr
(mm)
Between winding and stator core
230
2.0
4.5
2.0
4.5
Between inner and outer of motor
connection box
230
4.0
6.0
4.0
6.0
Distance through insulation
The distance through capacitor box is 2mm.
B
ANNEX B, THERMAL CUT-OUTS AND OVERLOAD RELEASES
N/A
B.1
Reliability of thermal cut-outs and overload
releases
Approved circuit breaker used.
N/A
Reliability test ............................................................:
N/A
B.2
Appreciable changing of setting of thermal cut-outs
and overload releases
N/A
C
Annex C, ELECTRONIC CIRCUITS
N/A
C.1
SCOPE
N/A
This annex applies to circuits comprising at least
one electronic component
N/A
C.2
DEFINITIONS
N/A
C.4
GENERAL CONDITIONS FOR THE TESTS
N/A
C.8
PROTECTION AGAINST ELECTRIC SHOCK
N/A
C.11
HEATING
N/A
C.12
LEAKAGE CURRENT
N/A
C.15
INSULATION RESISTANCE AND ELECTRIC STRENGTH
N/A
C.17
ABNORMAL OPERATION
N/A
C.20
CONSTRUCTION
N/A
C.25
PROVISION FOR EARTHING
N/A
C.27
CREEPAGE DISTANCES,CLEARANCES AND DISTANCES THROUGH
INSULATION
N/A
Summary of Contents for JTS-315LA
Page 2: ......
Page 3: ...8 JPW s CE declaration of conformity with latest directives and EN standards...
Page 4: ...9 CE certificates...
Page 5: ......
Page 6: ......
Page 17: ...Appendix A A1 A2 A3 A4...
Page 19: ...Parts Breakdown for JTS 315LA Table Saw...
Page 30: ......
Page 41: ......
Page 124: ...Circular Saw Bench...