Produkte
Products
Prüfbericht - Nr.:
Test Report No.
:
17706754 001
Seite 15 von 18
Page 15 of 18
4.2.2
Radiated Disturbance in the Frequency Range from 30MHz to 1000MHz
Result:
Passed
Test procedure
:
EN 55014-1:2006+A1+A2 and CISPR 16-1 series standards
The only electrical part that may generate RF noise incorporated in the sample is an
induction motor. According to the electrical characteristic of the induction motor, it cannot
produce disturbance power exceeding the limits for disturbance power prescribed by EN
55014-1:2006+A1+A2. Therefore, the EUT is deemed to meet the requirements of the EN
55014-1:2006+A1+A2 without actual testing.