Produkte
Products
Prüfbericht - Nr.:
Test Report No.
:
17706754 001
Seite 16 von 18
Page 16 of 18
5
Test Results I M M U N I T Y
The immunity test was not necessary for the EUT because it belongs to category I apparatus
according to EN 55014-2:1997+A1+A2, i.e.,
“Category I: Apparatus containing no electronic control circuitry.
Examples: motor operated appliances, lighting toys, track sets without electronic control
units, tools, heating appliances UV and IR radiators and apparatus containing components
such as electromechanical switches and thermostats.
Electric circuits consisting of passive components (such as radio interference suppression
capacitors or inductors, mains transformers and mains frequency rectifiers) are not
considered to be electronic control circuitry.”
According to clause 7.2.1 of EN 55014-2:1997+A1+A2, the EUT is deemed to fulfill the
relevant immunity requirements without actual testing.