BBDUDBHQBE±3DJHRI
5.3
Testing dispenser electrically
Requirement:
►
Outer door removed.
5.3.1
Measuring the coil
5.
Disconnect plug-and-socket connection.
Measure resistance on the coil.
Technical specifications EU:
Pulse voltage of coil:
320 V
Frequency: DC
Resistance:
11 k
Ω
± 1 k
Ω
Rinse aid capacity:
80 ml
Rinse aid amount at setting 1–6
1 ml per setting
Technical specificationsUSA:
Pulse voltage of coil:
165 V DC
Resistance:
2,67 k
Ω
± 210
Ω
Rinse aid capacity:
80 ml
Rinse aid amount at setting 1–6
1 ml per setting
Technical specifications EA (East Asia):
Pulse voltage of coil:
280 V DC
Resistance:
8,4 k
Ω
± 800
Ω
Rinse aid capacity:
80 ml
Rinse aid amount at setting 1–6
1 ml per setting
Technical specifications TC:
Pulse voltage of coil:
155 V DC
Resistance:
2,67 k
Ω
± 210
Ω
Rinse aid capacity:
80 ml
Rinse aid amount at setting 1–6
1 ml per setting
Summary of Contents for JDB9600AW
Page 41: ... B BDUDBHQBE 3DJH RI Representation of mobile elements Loading example ...
Page 43: ... B BDUDBHQBE 3DJH RI Representation of mobile elements Loading example ...
Page 44: ... B BDUDBHQBE 3DJH RI Loading example ...
Page 99: ... B BDUDBHQBE 3DJH RI Positioning the utensils 5 13 3 Gastronorm insert holder ...
Page 102: ... B BDUDBHQBE 3DJH RI 5 14 Installing childproof lock Requirement Worktop removed ...
Page 109: ... B BDUDBHQBE 3DJH RI 1 Remove 4 screws 1 Remove both chrome strips ...
Page 111: ... B BDUDBHQBE 3DJH RI 1 Remove screws 1 Remove 6 housing screws from the front door ...
Page 120: ... B BDUDBHQBE 3DJH RI 1 Install appliance and 2 install base panel ...
Page 125: ... B BDUDBHQBE 3DJH RI 1 Insert LEDs into the frame of the rinsing tank ...
Page 135: ... B BDUDBHQBE 3DJH RI ...
Page 153: ... B BDUDBHQBE 3DJH RI 5 32 2 Installation ...
Page 193: ......