BBDUDBHQBE±3DJHRI
5.6
Testing Aquastop valve electrically
1.
Loosing locking lever
2.
Fold the Cover with the inlet hose outward.
Technical specifications EU:
Nominal voltage:
220 ~ 240 V
Frequency: 50/60
Hz
Resistance:
4.2 k
Ω
± 1 K
Ω
Technical specifications TC / USA:
Nominal voltage:
110 ~ 127 V
Frequency: 60
Hz
Resistance:
990
Ω
± 50
Ω
1.
Disconnect plug-and-socket connection and measure the
resistance.