39 HomeRunner RBI User Manual – Rev 1.03a
SPECIFICATIONS
Power Input: 9 - 12VDC @ 300mA (not required with model 2412S PLM)
Front LEDs: “SEND” (Green), “RECV” (Yellow), “RUN” (Red)
Rear Connections: “NETWORK” (Ethernet, RJ45),
“SERIAL” (RS232, RJ21),
“PLM” (Power Line Modem, RJ45),
“12VDC IN” (9 - 12 VDC @300mA, 2.1mm coax)
Serial Port Pinout: 1=Transmit, 2=Ground, 3=Receive, 4=Not Used
Serial Port Baud Rate: up to 115,200 bps, asynchronous
Data Format: 8 Data Bits, No Parity, One Stop Bit
Delay Timers: 16 simultaneous (shared)
Dynamic Timers: 32
Variables: 256
Flags: 256
X-10: 256
Insteon Devices: 1024
Total System Links: 5000
Insteon Scenes: 500 max.
History Log: 512 lines (FIFO)
Message Log: 128 lines, 32 characters/line (FIFO)
Total User Memory: 2.9 MB
Maximum Events: 1024 or 50,000 bytes maximum compiled
Maximum Then Macros: 256 or 20,000 bytes maximum compiled
Dimensions: 5.5" x 4" x 1.5"
Net Weight (controller only): 0.5 lbs.
Required Operating System: Windows XP, Vista or 7 (32- or 64-bit)