balanced cable. To prevent strange behavior of the light effects, due to interferences, you must use a
90

Ω

to 120

Ω

terminator at the end of the chain. Never use Y-splitter cables, this simply won’t work!

Each light effect in the chain needs to have its proper starting address so it knows which commands
from the controller it has to decode.

How to set the DIP-switches to obtain the right starting address:

On the back of the Led Micro Scan you will see that each of the first 9 DIP-switches corresponds to
certain value:

Dip

#1

#2

#3

#4

#5

#6

#7

#8

#9

#10

Value

1

2

4

8

16

32

64

128

256

Invert slave

You can combine the values of these switches to become any starting address between 1 and 512:
Begin address = 01

switch 1=ON

values: 1

Begin address = 05

switch 1+3=ON

values: 1+4 = 5

Begin address = 09

switch 1+4=ON

values: 1+8 = 9

Begin address = 13

switch 1+3+4=ON

values: 1+4+8 = 13

Begin address = 62

switch 2+3+4+5+6=ON

values: 2+4+8+16+32 = 62

DMX-CONFIGURATION OF LED MICRO SCAN:

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

6/36

LED MICRO SCAN

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning products.

Always dry the parts carefully.

Clean the external optics at least once every 30 days.

Clean the internal optics at least every 90 days.

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

Mains Input:

AC 100 ~ 240V, 50/60Hz

Fuse:

250V 2A fast blow (20mm glass)

Sound Control:

Internal microphone

DMX connections:

3pin XLR male / female

DMX channels:

5

Lamp:

CREE 10W White LED

Size:

333 x 156 x 177mm (see drawing)

Weight:

3,0kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

Summary of Contents for LED Micro Scan

Page 1: ...ing Bedienungsanleitung Manual de instrucciones Manual do utilizador EN FR NL DE ES PT Copyright 2010 by BEGLEC NV t Hofveld 2C B1702 Groot Bijgaarden Belgium Reproduction or publication of the conten...

Page 2: ...s normas vigentes no seu pa s WARNING DANGER never expose the lens to direct sunlight even for a short period This may damage the light effect or even cause fire ATTENTION DANGER n exposez jamais la l...

Page 3: ...ION MANUAL JB SYSTEMS 2 36 LED MICRO SCAN This symbol means indoor use only This symbol means Read instructions This symbol determines the minimum distance from lighted objects The minimum distance be...

Page 4: ...this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installati...

Page 5: ...ousings fixations and installations spots ceiling truss suspensions should be totally free from any deformation When an optical lens is visibly damaged due to cracks or deep scratches it must be repla...

Page 6: ...pareil Ce symbole signifie uniquement pour usage l int rieur Ce symbole signifie Lire le mode d emploi Ce symbole repr sente la distance de recul minimum respecter c est dire la distance minimum entre...

Page 7: ...rit secondaire doit tre install de mani re ce qu aucune partie de l appareil ne puisse descendre de plus de 20 cm si le support principal tombe L appareil doit tre bien fix un montage balancement est...

Page 8: ...de chacune de ses pi ces doivent tre bien fix es et non corrod es Les niches fixations et structures de support plafond poutres suspensions doivent tre totalement intactes sans aucune d formation Lor...

Page 9: ...iteratuur belangrijke gebruik en onderhoudsinstructies vermeld staan betreffende dit onderdeel Dit symbool betekent het apparaat mag enkel binnenhuis worden gebruikt Dit symbool betekent Lees de handl...

Page 10: ...paraat moet goed worden vastgezet aan een vrij zwaaiende montering mag zelfs niet gedacht worden Bedek geen ventilatieopeningen anders zou dit oververhitting tot gevolg kunnen hebben NEDERLANDS HANDLE...

Page 11: ...leren en al zijn onderdelen moeten goed vastgedraaid zijn en mogen niet verroest zijn Behuizingen vastzetstukken installeringplaatsen plafond spanten schokbrekers mogen absoluut niet verwrongen zijn W...

Page 12: ...lierten Teilen im Ger teinneren welche eine gef hrliche Spannung f hren besteht Die Spannung ist so hoch das hier die Gefahr eines elektrischen Schlages besteht Das Ausrufezeichen im Dreieck weist den...

Page 13: ...tracht gezogen werden Ventilations ffnungen nicht abdecken da berhitzungsgefahr Betreiber mu sicherstellen dass die sicherheitsrelevanten und technischen Installationen vor Erstbetrieb fachm nnisch vo...

Page 14: ...Wartung sind folgende Punkte ganz besonders zu beachten S mtliche Schrauben zur Installation und Befestigung jeglicher Teile m ssen fest angezogen und rostfrei sein Geh use Befestigungsmaterialien un...

Page 15: ...la presencia de importantes instrucciones de operaci n y de mantenimiento tenidas en cuenta en el manual de uso Este s mbolo significa uso para el interior solamente Este s mbolo significa Lea las in...

Page 16: ...ninguna apertura de ventilaci n ya que esto podr a resultar en sobrecalentamiento El operador tiene que asegurarse de que las instalaciones relativas a seguridad maquinaria y t cnica est n aprobadas...

Page 17: ...del aparato y cualquiera de sus partes deben ser apretados fuertemente y no pueden estar corro dos Carcasas fijaciones y puntos de instalaci n techos armaduras suspensiones deber n estar totalmente li...

Page 18: ...iliza o e manuten o do produto Este s mbolo significa utiliza o unicamente em espa os fechados Este s mbolo significa Leia instru es Este s mbolo determina a dist ncia m nima dos objetos iluminados A...

Page 19: ...r ser fixa firmemente Uma instala o oscilante pode ser perigosa e n o dever ser efectuada N o cubra os orif cios de ventila o ou a unidade poder sobreaquecer O utilizador da unidade dever certificar s...

Page 20: ...da corrente e aguarde que a unidade arrefe a Durante a inspec o dever verificar os seguintes pontos Todos os parafusos utilizados nas pe as da unidade e na instala o dever o estar apertados firmement...

Reviews: