INSTALLATION INSTRUCTIONS (cont.)

10.  

Protect the acrylic bath surface from damage 
during installation with a suitable material, i.e., 
cardboard and/or plastic film.

 The acrylic surface 

of this bath has been provided with a protective film 
which helps protect the bath during shipment and 
installation. Additional protection may also be required 
to protect the acrylic surface during installation. If the 
bath is tiled in, remove the necessary portion of the 
film when installing the tile.

FIELD INSTALLATION OF THE MICROSILK

®

 PUMP

ASSEMBLY

The Jason MicroSilk

®

 system has been factory assembled 

following ETL and IAPMO guidelines. For shipping 
purposes, on some bath models, the MicroSilk

®

 Pump 

Assembly may be packaged separately and disconnected 
from the bath. 

NOTE: These instructions can also be found in the 
Installation, Operation and Maintenance manual of the 
separately packaged MicroSilk

®

 hydrotherapy bath 

unit. 

Fu ll  Su p p o r t   B a s e

Figure  3

Figure  4

WARNING:  SYSTEM UNDER PRESSURE – NEVER 
PERFORM MAINTENANCE WHILE SYSTEM IS RUNNING.

Note:

 Verify the MicroSilk

®

 Pump Assembly is the same 

unit that was provided for the bath being installed. The 
serial number listed on the label provided on the MicroSilk

®

 

Pump Assembly carton should match the serial number of 
the bath.

WARNING: Any modification to the equipment is not 
recommended and will VOID the manufacturer’s 
warranty.

To install the MicroSilk

®

 Pump Assembly to the bath, the 

following procedures must be followed.

Note:

 Do not install the MicroSilk

®

 Pump Assembly further 

than the length of the tubing that is factory installed on the 
bath. These tubing lengths have been designed for proper 
drainage of the system.

1.  Position the bath in the area of intended installation.

2.  Before beginning any work, the installer is to determine 

the proper location of the MicroSilk

®

 Pump Assembly 

and service access.

3.  Do not disconnect the plumbing lines that are secured 

to the bath with nylon tie straps 

(Figure 5)

.

Figure  5

Summary of Contents for forma Designer MicroSilk AirMasseur

Page 1: ...responsible for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been...

Page 2: ...minimum ventilation opening of 2 x 4 5 x 10 cm for the blower is required and should be designed to draw in indoor ambient air at a minimum of 72 F 22 C 4 Install the drain and overflow assembly to t...

Page 3: ...ration and Maintenance manual of the separately packaged MicroSilk hydrotherapy bath unit Full Support B ase Figure 3 Figure 4 WARNING SYSTEM UNDER PRESSURE NEVER PERFORM MAINTENANCE WHILE SYSTEM IS R...

Page 4: ...ed following E T L Guidelines During installation if remote mounting of the blower is desired or required the following procedures should be followed NOTE Do not remote mount the blower more than 15 f...

Page 5: ...Control Box The MicroSilk generator unit may be shippedseparatefromthebath Followtheinstructionsfor theMicroSilk PumpAssemblyFieldInstallationinthe Installation section of this owner s manual instruc...

Page 6: ...Standard Premier Edition Signature Edition Sani Design C leaning Syst em B lower C ont rol B oxes C ont rol Mount L2 L1 GROUND DEDIC ATED 2 4 0 V 5 0 or 6 0 Hz GFC I PROTEC TED SERVIC E NOTE USE THE A...

Page 7: ...e during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1...

Page 8: ...f Ugtxleg Hgocng Pgoc Nqcf Eqppgevlqp MgCrcf aKFW 288b Dnqygt OU Swor Ocng Pgoc Nlpg Eqppgevlqp MgCrcf Ecdng aEDN 169b Transducer Cables Transducer Cables PqvguB C Ulping Fgflecvgf 120X 60JD 20C IHEK...

Page 9: ...system see note B The MicroSilk pump s power cord should be plugged into the female cord connection on the ozone unit prewired to the control box C Eight pinmini DINterminalfortheMicroSilk AirMasseur...

Page 10: ...B The MicroSilk pump s power cord should be plugged into the female cord connection on the ozone unit prewired to the control box C Eight pinmini DINterminalfortheMicroSilk AirMasseur Keypad D The bl...

Page 11: ...ute pause before the purge cycle begins Once the purge cycle begins all indicators will light and the keypad operation will be disabled for two 2 minutes SIGNATURE EDITION MICROSILK AIRMASSEUR The Jas...

Page 12: ...es 50mm above the jets The inlet temperature should not exceed 40 C 104 F When bath is in use turn the unit Off before draining the water The bath unit and its plumbing are designed to drain after eac...

Page 13: ...gh speed mode Pressing the icon again begins the wave mode indicated by a slow flashing light Pressing the icon a third time will change the blower to pulse mode This is indicated by a rapid light fla...

Page 14: ...2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a...

Page 15: ...ll ensure a quick response on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY...

Page 16: ...a Refer to installer dealer b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make...

Page 17: ...cted c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage a Check that bl...

Page 18: ...er use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical histor...

Reviews: