background image

Page 1 of 3

Posh Solus Mk3 Rail Shower 1 Function Chrome (4*)

Plumbers, please ensure a copy of the Installation

Instructions are left with the end user for future reference

Installation Instructions

Step 2

Insert the rail, slider and soap dish.

into place.

Fix the rail in place using the rubber

bush and brass nut on both pillars. 
Replace chrome pillar caps.

• 

• 

• 

Step 3

To adjust slider position, push button to 

unlock and and release button to lock 

the slider.

• 

1850mm (Recommended)

680mm Rail

  580mm

Chrome Cap

FLOOR

Step 1

Remove chrome caps from each pillar.

Mount the top and bottom pillars in desired

position with the screws and wall plugs.

Check the mounts are vertically aligned.

• 

Rail

Slider

Elbow

(if supplied)

Brass Nut

*This product must be installed in

compliance with all relevant regional 

regulations. 

It is the responsibility of the installer to 

ensure a waterproof seal is achieved 

between the product and mounting 

surface. If in doubt about the quality of 

the seal, remove the product and 

reinstall using silicone to ensure a seal is 

achieved. 

All pipe work must be thoroughly flushed 

prior to the installation of the hose. 

After installation all connections must be 

checked for leaks. 

All outlets used primarily for personal 

hygiene shall deliver water at a safe 

temperature as per regional regulations.

• 

• 

• 

• 

 

IMPORTANT: 

Please read all of the 

instructions before installation.

General:

• 

Wall Plug

(Recommended)

Chrome Cap

Rubber Bush

Screw

Slider button

Important Installation Considerations

1. NOTE: Some showers may not provide an effective shower when used

with gravity fed heated water systems or where pressures are less

than 150kPa at the outlet. Additionally showers with flow rates of less

than 9L/min may not allow the following to function correctly:

_ some instantaneous water heaters

_ some tempering valves

_ some thermostatic mixing valves

2. Some shower heads only operate correctly when hot and cold water

supplies are both mains pressure and may not be suitable for some

instantaneous hot water services.

3. When water pressure is in excess of 500kPa a pressure limiting device

is required in accordance with AS/NZS 3500 1.12 recommendation

www.methven.com

Methven warrants this product against manufacturing defects and that it is suitable for use 

under the general operating conditions specified in this instruction sheet. However, regional 

regulations apply and may affect your warranty. Please refer to 

customer service for full details.

New  Zealand

0800 804 222

Australia

1300 638 483

UK

0800 195 1602

98-0284

ISSUE A

DECEMBER 2015

Technical Specifications: 

Operating Pressure:

Min: 150kPa/1.5bar

Max: 500kPa/5.0bar*

Optimum: 150kPa/1.5bar - 500kPa/5bar

Operating Temperature:

Hot: Max 80°C*

Cold: Min 5°C

Inlet Connections:

All ½" BSP

* Regional specific regulations apply. 
Please refer to your warranty statement at 

www.methven.com

TWIN SHOWER SYSTEM

Installation Guide

Recommended installation of pressure limiting

valve if supply exceeds 500kPa

NOTE:

- After installation all connections must be 

  checked for leaks

- All installations must be carried out in 

  compliance with relevant water regulations*.

Important Installation Considerations

1. NOTE: Some showers may not provide an effective shower when used

with gravity fed heated water systems or where pressures are less

than 150kPa at the outlet. Additionally showers with flow rates of less

than 9L/min may not allow the following to function correctly:

_ some instantaneous water heaters

_ some tempering valves

_ some thermostatic mixing valves

2. Some shower heads only operate correctly when hot and cold water

supplies are both mains pressure and may not be suitable for some

instantaneous hot water services.

3. When water pressure is in excess of 500kPa a pressure limiting device

is required in accordance with AS/NZS 3500 1.12 recommendation

www.methven.com

Methven warrants this product against manufacturing defects and that it is suitable for use 

under the general operating conditions specified in this instruction sheet. However, regional 

regulations apply and may affect your warranty. Please refer to 

customer service for full details.

New  Zealand

0800 804 222

Australia

1300 638 483

UK

0800 195 1602

98-0284

ISSUE A

DECEMBER 2015

Technical Specifications: 

Operating Pressure:

Min: 150kPa/1.5bar

Max: 500kPa/5.0bar*

Optimum: 150kPa/1.5bar - 500kPa/5bar

Operating Temperature:

Hot: Max 80°C*

Cold: Min 5°C

Inlet Connections:

All ½" BSP

* Regional specific regulations apply. 
Please refer to your warranty statement at 

www.methven.com

TWIN SHOWER SYSTEM

Installation Guide

Recommended installation of pressure limiting

valve if supply exceeds 500kPa

NOTE:

- After installation all connections must be 

  checked for leaks

- All installations must be carried out in 

  compliance with relevant water regulations*.

97-2821

Apr-2018

Reviews: