3 Specifications
Reference temp: + 20 °C
3.1 General
Measurement interval
2 ms / 5 ms / 10 ms / 20 ms / 50 ms / 100 ms / 200 ms / 500 ms / 1 s / 2 s / 5 s
(Under certain circumstances, frequency measurements can take several
measurement intervals)
Supply voltage
AC Version
90…264 VAC (47...63 Hz) / 120VDC … 370VDC
DC Version
18…36 VDC
Isolation voltage
AC Version
3000 VAC (of the AC/DC power supply)
DC Version
1500 VDC (of the DC/DC converter)
Isolation
Galvanic isolation between:
•
Supply
•
Sensor input incl. sensor supply, analog input, CAN, Display
•
Binary input 1
•
Binary input 2
•
Analog output 1
•
Analog output 2
•
Relay outputs
•
Open Collector output 1
•
Open Collector output 2
•
Ethernet interface
Power consumption
T601
without Display
T601 with D211
(Cable version)
T601 with D201
(BlueTooth® version)
P min.
(W)
P max.
(W)
P min.
(W)
P max.
(W)
P min.
(W)
P max.
(W)
AC Vers.
110 VAC
5.0
11.0
6.8
13.0
5.1
11.2
230 VAC
8.0
15.2
10.0
16.7
8.1
15.4
DC Vers.
18 VDC
3.0
7.5
4.4
8.8
3.2
7.7
24 VDC
3.0
7.4
4.4
8.7
3.2
7.6
36 VDC
3.2
7.5
4.6
8.8
3.4
7.7
Power supply bridging
with P max.
T601
without Display
T601 with D211
(Cable version)
T601 with D201
(BlueTooth® version)
AC Vers.
110 VAC
39 ms
37 ms
31 ms
230 VAC
200 ms
190 ms
170 ms
DC Vers.
18 VDC
7 ms
6.8 ms
5.5 ms
24 VDC
23 ms
22 ms
19 ms
25 VDC
26 ms
25 ms
22 ms
36 VDC
70 ms
67 ms
55 ms
Operating temperature
AC Version
-
25 °C…+50 °C
DC Version
-
40 °C…+70 °C
Storage temperature
AC Version
-
40 °C…+85 °C
DC Version
AC Version
450 g
DC Version
400 g
Sealing to DIN
EN 60529
IP 20