7.7.8 Direction Sensing
To configure direction sensing go to <Configuration>, <System>.
To use direction sensing, 2 sensors must be connected that
optimally exhibit 90° phase shift (minimum 10°).
The signal sequence that corresponds to clockwise rotation of the
shaft must be defined
Clockwise:
S1 before S2
/ S2 before S1
7.7.9 Analog Input Range
To configure the analog input go to <Configuration>, <System>.
The current value may be defined for inclusion in System Limits.
The start value refers to 0/4mA according to the definition and the
end value to 20mA input.
Start value:
-
999'999 …
0.0
… 999’999
End value:
-
999'999 …
100.0
… 999’999
7.7.10 Dynamic Error
Go to <Configuration>, <System>.
f
f
S
S
Difference
2
1
f
S1
: Sensor 1 frequency
f
S2
: Sensor 2 frequency
This function is only available used when both sensor inputs are
used. This function has influence only on Sensor alaram.
Deviation:
0.0 …
100.0
… 999’999
If the speed difference is bigger than this value, then Dynamic error
is signalled.