![Jaquet MultiTasker T601 Instruction Manual Download Page 35](http://html1.mh-extra.com/html/jaquet/multitasker-t601/multitasker-t601_instruction-manual_3370759035.webp)
Instruction Manual T601
JAQUET AG
Revision: 004
35/73
To read out the contents of the event recorder and then delete it go
to <Online>, <Read and delete memory>.
After confirming with OK that you wish to read the data, it is loaded
from the tachometer. That can take a few seconds. When reading
the data you can define the destination to save it. For safety reasons
you will be asked again whether you wish to delete the data.
NB:
After deleting the data it cannot be restored.
If you only wish to read the data from the event recorder got to
<Online>, <Read memory>
After confirming with OK that you wish to read the data, it is loaded
from the tachometer.
If you only wish to delete the event recorder data go to <Online>,
<Delete memory>, then confirm with OK.
7.7 Configuring
The factory defaults are written in
bold
.
7.7.1 Configure Speed Sensors
Go to <Configuration>, <Sensor>.
To connect the sensor see chapter 6.1.2 Terminal A.
5 Parameters are used to configure the sensor:
Type:
powered
/ not powered
Resistor:
used /
not used
Min. current:
0.5
mA … 35mA
Max. current:
0.5mA …
35
mA
Trigger level:
fixed 3V / min 57mV
pp
/
min 500mV