7.6.2 Reading configuration from the T601
When the configuration software is started the configuration file is
automatically transferred to the PC. To up load the file again go to
<Online>, <Read parameters> and confirm with Enter.
NB
: The live parameter data will be overwritten.
7.6.3 Writing a configuration to the T601
Once the configuration is prepared it can be written to the T601.
Go to <Online>, <Write parameters>. The parameters will then be
sent to the tachometer. The process takes approximately 10
seconds. The T601 status during this period is described in chapter
8.7 Behaviour during Configuration.
If no connection can be established, the process is repeated 3 times
and then abandoned.
NB:
Actual tachometer data will be over written and the unit is in
error mode during this period.
7.6.4 Compare data
If you like to compare a PC configuration file with that in the T601,
first open the file and then go to <Online>, <Compare Data>.
The actual file is then uploaded from the T601 and compared with
the software parameters. A dialogue window will then appear
showing whether the files are identical or not.
7.6.5 Read and/or Delete Event Recorder
This function is available since version 0.99.