Alarm name
Outline
Probable cause
Confirmation item
STS2 LED
AIM LED
[GPS]
Internal GPS
signal reception
error
Blocking occurred. The built-in GPS cannot
determine position
information. Confirm
whether blocking state is
entered. If this alarm is
frequently displayed even
after blocking is cleared, the
unit may be faulty.
[IMPACT]
Excessive
impact on ADE
A strong impact
can be applied to
ADE for a long
time.
Since a strong impact is
applied to ADE for a long
time, mechanical failure
possibility is increasing.
Check the ADE installation
by referring to "E.6 Problem
related to vibration and
impact " in this manual and
"Appendix D Precautions for
ADE equipment" and "2.2.2
Recommended prop
example" in the installation
manual.
ST3 LED
CM
[COMM_CM]
CM
communication
error
Unit reboot due to
automatic
upgrade
Since CM is rebooted when
it is automatically upgraded
from SAS, a CM
communication error
temporarily occurs.
If this alarm is displayed
frequently or for an
extended period of time, the
unit may be faulty.
Unit is reset.
ST4 LED
BUC
[COMM_BUC]
BUC
communication
error
Unit reboot due to
automatic
upgrade
Since BUC is rebooted
when it is automatically
upgraded from SAS, a BUC
communication error
temporarily occurs.
If this alarm is displayed
frequently or for an
extended period of time, the
unit may be faulty.
Unit is reset.
Communication
error due to poor
contact
Confirm the coaxial cable
connection.
[LOUNLOCK]
Local oscillator
unlock
Poor contact of
coaxial cable for
transmission
Confirm the connection of
coaxial cable for
transmission.
Summary of Contents for JUE-60GX
Page 2: ......
Page 26: ...Section 1 Inmarsat GX systems 1 6...
Page 34: ...Section 2 Introduction of the JUE 60GX 2 8...
Page 102: ...Section 6 Maintenance 6 2...
Page 104: ...Section 7 After sales service 7 2...
Page 106: ...Section 8 Specification 8 2...
Page 118: ...Appendix C Initializing the settings to the factory default state C 2...
Page 120: ...Appendix D List of Initial Values Version 0100 D 2...
Page 140: ...Appendix F LED of BDE F 6...
Page 144: ...Appendix G Abbreviations and Glossary G 4...
Page 146: ...Appendix H JRC Network H 2...
Page 148: ...Appendix I Hazardous substances of Electrical and electronic Products I 2...
Page 149: ......