8.0 Technical Data and Specifications
PARAMETER
WMX
No. of Channels:
12
Input Power Requirements:
3 phase Star only
415 VAC Phase-Phase @ 40A/phase
protected at 50A/phase max
Full size neutral required
User Protection
Safety Extra-low voltage and Earthed enclosure
Impulse withstand voltage 2500V
Maximum Power / Channel
2.4 kW
Minimum Power/Channel
25W
Maximum Dissipation
<24 W/channel (<300 W total)
Maximum Ambient Temp
40ºC
Control Signal
ANSI E1.11 DMX-512-A Protocol
DMX Input
5 pin AXR male / female
Test Function Level
Individual Channels @ 100%
Group Channels @ 20% steps
LED Indicators
DMX, FAULT,
Phases A, B, and C
Output Protection
12 x 10 Amp thermal/magnetic circuit breakers
Over-temperature cutout
Electronic: 83
o
C rising, 78
o
C falling
Mechanical: 90
o
C
Over-voltage cutout
Average 290VAC
Ingress protection
IP20
Size (mm) - Dimmer
- Shipping
485mm (w) x 490mm (h) x 145mm (d)
630mm (w) x 580mm (h) x 190mm (d)
Weight
16.6 kg net / 19.0kg gross
Table 8.1: Technical Data And Specifications