EEN (Exposure Enable) Function
Perform external output for the timing at which video is accumulated to the sensor.
The signal is output to the DC IN / TRIG IN connector (12-pin round) or AUX
connector.
Example: Output to DC IN/TRIG IN connector (12-pin round)
Trigger
Exposure
EEN
( Internal / External )
Test Pattern Function
You can display the following types of test patterns (Off, White, GrayPattern1,
GrayPattern2, ColorBar). Video output is not possible while a test pattern is being
executed. This function is not dependent on gain and offset values that have already
been configured.
◇
This function cannot be saved as the initial state of the camera.
Electronic Shutter
When you use this function, you can set the exposure to a preconfigured
accumulation time, regardless of the line rate.
• Variable range: 3 μs to 15.149 ms
• Variable unit: 0.01 μs (1clk)
• Supported operation modes: When Trigger Mode ON, Exposure Mode Timed
◇
You can also save the setting and have it applied whenever the power is
subsequently turned on, but this requires additional operations.
In “Trigger Mode OFF, Exposure Mode Timed” mode, the line rate configured will be the
maximum value at which the shutter operates. However, in “Trigger Mode ON,
Exposure Mode Timed” mode, the input trigger period will be the maximum value.
Caution
SW-8000Q-10GE/SW-8000Q-SFP
— 38 —
Summary of Contents for SW-8000Q-10GE
Page 8: ...Parts Identification SW 8000Q 10GE SW 8000Q SFP SW 8000Q 10GE 10 SW 8000Q SFP SW 8000Q SFP 8 ...
Page 66: ...Spectral Response Wave length nm Relative Response SW 8000Q 10GE SW 8000Q SFP 66 ...
Page 68: ...M52 mount SW 8000Q 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000Q 10GE SW 8000Q SFP 68 ...
Page 69: ...F mount SW 8000Q SFP F SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 69 ...
Page 70: ...M52 mount SW 8000Q SFP M52 SW 8000Q 10GE SW 8000Q SFP Dimensional tolerance 0 3mm Unit mm 70 ...