Setting range
Default value
Description
Configure Auto Level Control settings.
0: Peak Channel,
1: Selected Channel
1: Selected Channel
0:Red,
1:Green,
2:Blue
1: Green
30〜95
50
Set the target level for ALC. (unit: %)
―
Low Right
Select the area for which to configure [ALCAreaEnable].
[Setting range]
0:Low Right, 1:Low Mid-Right, 2:Low Mid-Left, 3:Low Left
4:Mid-Low Right, 5:Mid-Low Mid-Right, 6:Mid-Low Mid-Left, 7:Mid-Low Left
8:Mid-High Right, 9:Mid-High Mid-Right, 10:Mid-High Mid-Left, 11:Mid-High Left
12:High Right, 13:High Mid-Right, 14:High Mid-Left, 15:High Left
ALCAreaEnable
True, False
True
Enable/disable the photometry area selected in [ALCAreaSelector].
True, False
True
True: Operate ALC with all areas designated as photometry areas, regardless of the
individual enabled/disabled photometry area states configured in [ALCAreaSelector].
False: Operate ALC according to the individual enabled/disabled photometry area states
configured in [ALCAreaSelector].
1〜100
90
Set the response speed. (100 is the fastest.)
100 〜
100
Set the minimum value for the ExposureAuto(ASC) control range.
―
ー
Set the maximum value for the ExposureAuto(ASC) control range.
100 〜
100
Set the minimum value for the GainAuto(ASC) control range.
〜 1600
1600
Set the maximum value for the GainAuto(ASC) control range.
0: Off, 2: ASC, 3: AGC
0:Off
Allows confirmation of the current operation area during ALC operation.
―
Idle
Allows confirmation of the AGC, ASC, and AWB convergence status.
[Status]
1:ExecutingASC, 2:ExecutingAGC, 3:ExecutingASCandAGC, 4:ExecutingAWB
5:ExecutingASCandAWB, 6:ExecutingAGCandAWB, 7:ExecutingASCandAGCandAWB,
8:Convergent, 9:ConditionError, 255:Idle
Configure settings for JAI white blemish correction.
True, False
True
Enable/disable blemish correction.
ー
ー
Execute blemish detection.
This command can not be executed under the following conditions.
・When no image is output
・Outputting TestPattern
・In Sequencer mode
・In Overlap MultiRoi mode
・In single ROI mode
・In Decimation mode
・In Binning mode
ー
ー
Display the blemish detection results.
0:Idle
1:Succeeded
3:Error2 - exceeded max compensation number
4:Error3 - could not detected
5:Error4 - timeout
ー
ー
Save the location information of detected blemishes.
1 〜 100
10
Set the blemish detection threshold.
1 〜 256
1
Select the index for the target blemish coordinates
(BlemishDataPosition X/Y).
BlemishCompensationPositionX
ー
-1
Display the X coordinate (horizontal pixel position) of the target blemish
selected in [BlemishCompensationIndex].
You can also manually enter the X coordinate of the blemish you want to correct.
[Setting range] GOX-2402MC-PGE: -1〜1919
GOX-3201MC-PGE: -1〜2047
GOX-5103MC-PGE: -1〜2447
GOX-8901MC-PGE: -1〜4095
GOX-12401MC-PGE: -1〜4095
BlemishCompensationPositionY
ー
-1
Display the Y coordinate (vertical pixel position) of the target blemish selected
in [BlemishCompensationIndex].
You can also manually enter the Y coordinate of the blemish you want to correct.
[Setting range] GOX-2402MC-PGE: -1〜1119
GOX-3201MC-PGE: -1〜1535
GOX-5103MC-PGE: -1〜2047
GOX-8901MC-PGE: -1〜2159
GOX-12401MC-PGE: -1〜2999
BlemishCompensationDataClear
ー
ー
Delete detected or specified blemish information selected in
[BlemishCompensationIndex].
0 〜 256
0
Display the number of target blemishes.
BlemishCompensationNumber
BlemishCompensationIndex
BlemishDetectThreshold
BlemishStore
BlemishDetect
BlemishEnable
BlemishDetectionResult
AutoGainControlGainRawMax
AutoGainControlGainRawMin
AutoShutterControlExposureMax
AutoShutterControlExposureMin
ALCAreaEnableAll
Item
ALCControlRatio
ALCStatus
ALCAreaSelector
ALCReference
n) AutoLevelControl
ALCControlReference
ALCControlChannel
AutoControlStatus
o) BlemishControl
—
72
—
Go-X Series GigE Vision I/F
Summary of Contents for Go-X Series
Page 79: ...Go X Series GigE Vision I F Spectral Response GOX 2402MC PGE 79 ...
Page 80: ... 80 Spectral Response GOX 3201MC PGE Go X Series GigE Vision I F ...
Page 81: ... 81 Spectral Response GOX 5103MC PGE Go X Series GigE Vision I F ...
Page 82: ...Go X Series GigE Vision I F Spectral Response GOX 8901MC PGE 82 ...
Page 83: ...Go X Series GigE Vision I F Spectral Response GOX 12401MC PGE 83 ...
Page 84: ... 84 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series GigE Vision I F ...