Go-X Series GigE Vision I/F
■
During Continuous operation ([Frame Start] trigger is [Off])
FR_Cont[Hz] = MIN(Interface_FR, Sensor_FR)
■
When [TriggerMode] is [On] ([Frame Start] trigger is [On])
First, calculate the maximum OverlapTime value for the shortest trigger cycle.
MaxOverlapTime_TrOlrd[us] = (1000000/FR_Cont) - (14 x H_period)
・
When ExposureTime
≦
MaxOverlapTime_TrOlrd
FR_TrOlrd[Hz] = FR_Cont
(Same as during Continuous operation)
・
When ExposureTime > MaxOverlapTime_TrOlrd
Non-OverlapExposureTime_TrOlrd = ExposureTime - MaxOverlapTime_TrOlrd
FR_TrOlrd[Hz] = 1000000/{ (1000000/FR_Cont) + Non-OverlapExposureTime_TrOlrd }