Timing chart (GOX-8901MC-PGE)
— 38 —
Go-X Series GigE Vision I/F
Next trigger disabled
Next trigger
Input enabled
B
Exposure time
Trigger
Sensor
Exposure
Exposure
Active
Readout
■
When [ExposureMode] is [Timed]
• FrameStartTrigger On
A (Frame Period)
PixelFormat
Frame Period [A] (usec)
Period From Trigger start edge to
Exposure start [B] (usec)
Mono8
77520
66.2
Mono10/Mono12
156251
132
Mono10Packed/Mono12Packed
116280
132.1
Bayer8
77520
66.2
Bayer10/Bayer12
156251
132
Bayer10Packed/Bayer12Packed
116280
132.1
Horizontal Binning On
Mono8
47847
66.3
Mono10
96154
132.1
Mono10Packed
96154
132.1
Mono8
47847
66.3
Mono10
96154
132.1
Mono10Packed
96155
132.1
Mono8
47847
66.3
Mono10
96155
132.1
Mono10Packed
96155
132.1
Vertical Binning On
Binning Off
Horizontal Binning On & Vertical Binning On
Summary of Contents for Go-X Series
Page 79: ...Go X Series GigE Vision I F Spectral Response GOX 2402MC PGE 79 ...
Page 80: ... 80 Spectral Response GOX 3201MC PGE Go X Series GigE Vision I F ...
Page 81: ... 81 Spectral Response GOX 5103MC PGE Go X Series GigE Vision I F ...
Page 82: ...Go X Series GigE Vision I F Spectral Response GOX 8901MC PGE 82 ...
Page 83: ...Go X Series GigE Vision I F Spectral Response GOX 12401MC PGE 83 ...
Page 84: ... 84 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series GigE Vision I F ...