— 41 —
Go-X Series GigE Vision I/F
■
When [ExposureMode] is [TriggerWidth]
(Next trigger disabled)
Next trigger
Input enabled
B
ExposureTime
Trigger
Sensor
Exposure
Exposure
Active
Readout
A (Frame Period)
D
C
• FrameStartTrigger On
PixelFormat
Frame Period [A] (usec)
Period From Trigger start edge
to Exposure start [B] (usec)
Period From Trigger end to
Exposure end [C] (usec)
Period From Exposure end to next
Trigger start [D] (usec)
Mono8
66226
66.2
66.2
240.6
Mono10/Mono12
133334
132.1
132.1
482.8
Mono10Packed/Mono12Packed
133334
132.1
132.1
482.8
Bayer8
66226
66.2
66.2
240.6
Bayer10/Bayer12
133334
132.1
132.1
482.8
Bayer10Packed/Bayer12Packed
133334
132.1
132.1
482.8
Horizontal Binning On
Mono8
66226
66.3
66.3
240.6
Mono10
133334
132.1
132.1
482.8
Mono10Packed
133334
132.1
132.1
482.8
Mono8
66226
66.2
66.2
240.6
Mono10
133334
132.1
132.1
482.8
Mono10Packed
133334
132.1
132.1
482.8
Mono8
66226
66.2
66.2
240.6
Mono10
133334
132.1
132.1
482.8
Mono10Packed
133334
132.1
132.1
482.8
Binning Off
Vertical Binning On
Horizontal Binning On & Vertical Binning On
Summary of Contents for Go-X Series
Page 79: ...Go X Series GigE Vision I F Spectral Response GOX 2402MC PGE 79 ...
Page 80: ... 80 Spectral Response GOX 3201MC PGE Go X Series GigE Vision I F ...
Page 81: ... 81 Spectral Response GOX 5103MC PGE Go X Series GigE Vision I F ...
Page 82: ...Go X Series GigE Vision I F Spectral Response GOX 8901MC PGE 82 ...
Page 83: ...Go X Series GigE Vision I F Spectral Response GOX 12401MC PGE 83 ...
Page 84: ... 84 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series GigE Vision I F ...
Page 88: ... 88 Revision Date Changes Revision history Go X Series GigE Vision I F ...