Trigger Activation
This command can select how to activate the trigger.
l
Rising edge
: At the rising edge of the pulse, the trigger is activated.
l
Falling edge
: At the falling edge of the pulse, the trigger is activated.
l
Level High
: During the high level of trigger, the accumulation is activated
l
Level Low
: During the low level of trigger, the accumulation is activated
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Camera Settings
JAI Custom Trigger
Mode Name
Trigger Activation Setting
Trigger
Selector
Trigger
Option
Rising
Edge
Falling
Edge
Level
High
Level
Low
Trigger
Mode
Exposure
Mode
Frame
Start
On
Timed
Off
EPS Trigger
✓
✓
On
Timed
RCT
RCT Trigger
✓
✓
On
Trigger
Width
Off
PWC Trigger
✓
✓
Trigger Overlap
On this camera, the trigger overlap function is fixed to Readout.