GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 39 -
Pulse Generator Clear Source
The following clear source can be selected as the pulse generator clear signal.
Pulse Generator
Clear Source Item
Description
Low
Connect Low level signal to Clear Source for the pulse generator.
Default setting
High
Connect High level signal to Clear Source for the pulse generator.
Frame Trigger Wait
Connect Frame Trigger Wait signal to Clear Source for the pulse generator.
Frame Active
Connect Frame Active signal to Clear Source for the pulse generator.
Exposure Active
Connect Exposure Active signal to Clear Source for the pulse generator.
FVAL
Connect FVAL signal to Clear Source for the pulse generator.
LVAL
Connect LVAL signal to Clear Source for the pulse generator.
Action 0 Out
Connect Action 0 output signal to Clear Source for the pulse generator.
Action 1 Out
Connect Action 1 output signal to Clear Source for the pulse generator.
User 0 Out
Connect User 0 output signal to Clear Source for the pulse generator.
User 1 Out
Connect User1 output signal to Clear Source for the pulse generator.
Line 5 Opt 1 In
Connect Opt 1 In signal to Clear Source for the pulse generator.
Nand0 Out
Connect NAND 0 output signal to Clear Source for the pulse generator.
Nand1 Out
Connect NAND 1 output signal to Clear Source for the pulse generator.
Pulse Generator Inverter
Clear Source Signal can have polarity inverted.
Pulse Generator Setting table
Display Name
Value
Clock Pre-scaler
1 to 4096
Pulse Generator Clock (MHZ)
[Pixel Clock:48 MHz]÷[Clock Pre-scaler]
Pulse Generator Selector
- Pulse Generator 0
- Pulse Generator Length
1 to 1048575
- Pulse Generator Length (ms)
([Clock Source]÷[Clock Pre-scaler])
-1
x [Pulse Generator Length]
- Pulse Generator Frequency (Hz)
[ Pulse Generator Length (ms)]
-1
- Pulse Generator Start Point
0 to 1048574
- Pulse Generator Start Point (ms)
([Clock Source]÷[Clock Pre-scaler])
-1
x [Pulse Generator Start Point]
- Pulse Generator End Point
1 to 1048575
- Pulse Generator End Point (ms)
([Clock Source]÷[Clock Pre-scaler])
-1
x [Pulse Generator End Point]
- Pulse Generator pulse-width (ms)
[ Pulse Generator End Point (ms)] - [ Pulse Generator Start Point (ms)]
- Pulse Generator Repeat Count
0 to 255
Summary of Contents for GO-5000M-PGE-UV
Page 46: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 46 Output Timing Vertical Vertical Timing ...
Page 55: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 55 How to Determine the Maximum Frame Rate ...
Page 60: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 60 ALC Channel Area ...
Page 74: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 74 Multi ROI Setting Example ...
Page 86: ...GO 5000M PGE UV User Manual Ver 1 2 Miscellaneous 86 Spectral Response ...