![JAI GO-5000M-PGE-UV User Manual Download Page 54](http://html.mh-extra.com/html/jai/go-5000m-pge-uv/go-5000m-pge-uv_user-manual_631513054.webp)
GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 54 -
Acquisition Start
This is the command to start the capture.
Acquisition Stop
This is the command to stop the capture.
Acquisition Frame Rate
With Trigger OFF, the default frame rate of the camera is based on the specified ROI. The smaller the
ROI, the faster the default frame rate. However, it is possible to specify a free-running frame rate (i.e.,
no trigger needed) that is slower than the default rate. This can be useful when a longer exposure time
is needed for a specific ROI.
Modification of the frame rate is done by entering a value in the AcquisitionFrameRate control
corresponding to the frame frequency. Allowed values range from 4172 Hz to 0.125 Hz for this
camera, however if the value entered is less than the time required for the default frame rate, the
setting is ignored, and the default frame rate is used. For example, the minimum frame period for the
smallest possible ROI (1 line) requires 4172 Hz (fps) in 8-bit mode, so any entry more than 4172 (fps)
will always be ignored.
* If binning mode is on, it can run up to 5121 (fps).
The setting range in Acquisition Frame Rate is:
Shortest
to
Longest
Inverse number of time required to drive all pixels in the area set by ROI command or
inverse number of time required to transmit one frame data
to
0.125 Hz (fps) =
8 seconds
For the above setting, Acquisition Frame Rate is used, and its unit is Hz (fps).
Acquisition Frame Rate: 4172 Hz (fps) to 0.125 Hz (fps)
Note:
The acquisition frame rate may be limited to the maximum value which will fit within the
GigE bandwidth.
Summary of Contents for GO-5000M-PGE-UV
Page 46: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 46 Output Timing Vertical Vertical Timing ...
Page 55: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 55 How to Determine the Maximum Frame Rate ...
Page 60: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 60 ALC Channel Area ...
Page 74: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 74 Multi ROI Setting Example ...
Page 86: ...GO 5000M PGE UV User Manual Ver 1 2 Miscellaneous 86 Spectral Response ...