GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 31 -
ActionGroupMask
Sets the mask value for the selected action signal in a 32-bit register. This value is compared against
the group mask value of the ACTION_CMD message to determine if the message should be ignored
or acted upon. A logical AND operation is used and must produce a non-zero result or else the
message is ignored.
ActionGroupKey
Sets the group key value for the selected action signal in a 32-bit register. This value must match the
group_key value of the ACTION_CMD message in order for the message to be acted upon.
GPIO
This is a general interface for input and output and controls input and output for trigger signals or valid
signals and pulse generator. By using this interface, you can control an external light source, make a
delayed function to input a trigger signal or make a precise exposure control with PWC trigger.
Basic Block Diagram
Summary of Contents for GO-5000M-PGE-UV
Page 46: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 46 Output Timing Vertical Vertical Timing ...
Page 55: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 55 How to Determine the Maximum Frame Rate ...
Page 60: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 60 ALC Channel Area ...
Page 74: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 74 Multi ROI Setting Example ...
Page 86: ...GO 5000M PGE UV User Manual Ver 1 2 Miscellaneous 86 Spectral Response ...