AD-081CL
- 38 -
8.4
AD-081CL
Command list
Command
Format
Parameter
Remarks
A – General settings and utility commands
゙
1
Echo Back
EB
=[Param.]<CR><LF>
EB?<CR><LF>
0=Echo off
1=Echo on
Off at power up
2
Camera Status
Request
ST
?<CR><LF>
Actual setting
3
Online Help Request
HP
?<CR><LF>
Command list
4
Firmware Version
VN
?<CR><LF>
3 digits, (e.g.)
100 = Ver. 1.00
5
Camera ID Request
ID
?<CR><LF>
Max 10 characters
6
Model Name Request
MD
?<CR><LF>
Max 10 characters
7
User ID
UD
=[Param.]<CR><LF>
UD?<CR><LF>
User can save and
load free text. (16
or less characters)
B – BW1, BW2 Common settings
1
Output Mode
IS
=[Param.]<CR><LF>
IS?<CR><LF>
0 = SYNC
1 = Separate
2
V Binning
BI1
=[Param.]<CR><LF>
BI1?<CR><LF>
0 = OFF
1 = ON
3
One-push AYB
AYB
=[Param.]<CR><LF>
O = One push AYB activated
4
Inquire the status
after one–push AYB
AYB?<CR><LF>
5
AYB area
YA
=[Param.]<CR><LF>
YA?<CR><LF>
0=Full area 1=Upper left
2=Upper mid 3=Upper right
4=Middle left 5=Middle
6=Mid. Right 7=Lower left
8=Lower mid. 8=Lower right
C – Shutter
1
Shutter Mode
SM1
=[Param.]<CR><LF>
SM1?<CR><LF>
0=Preset Shutter
1=Programmable exposure
For Imager BW1
SM2
=[Param.]<CR><LF>
SM1?<CR><LF>
For Imager BW2
2
Preset Shutter
SH1
=[Param.]<CR><LF>
SH1?<CR><LF>
0=Off, 1=1/60, 2=1/100,
3=1/120, 4=1/250, 5=1/500,
6=1/1000, 7=1/2000,
8=1/4000, 9=1/8000
10=1/16000, 11=1/50000
Available when
SM1=0
3
Preset Shutter
SH2
=[Param.]<CR><LF>
SH2?<CR><LF>
0=Off, 1=1/60, 2=1/100,
3=1/120, 4=1/250, 5=1/500,
6=1/1000, 7=1/2000,
8=1/4000, 9=1/8000
10=1/16000, 11=1/50000
Available when