AD-081CL
- 36 -
8.
Configuring Camera
8.1
Serial communications
All configuration of the AD-081CL camera is done by LVDS via Camera Link. Baud rate is 9600
bps. The camera can be set up from a PC running terminal emulator software, or through a
graphical user interface (GUI) using JAI's camera control software.
Below is the description of the ASCII-based short command protocol.
Communication Settings
Protocol.
Transmit setting to camera:
NN=
Parameter
<CR><LF>
(NN is any kind of command. Capital or small letters.)
The camera answers:
COMPLETE<CR><LF>
To have all communication visible on the emulator screen, start with:
EB=1<CR><LF>
The camera answers:
COMPLETE<CR><LF>
Transmit request command to camera:
NN?<CR><LF>
(NN is any kind of command.)
The camera answers:
NN=
Parameter
<CR><LF>
Transmit the following to have the camera actual setting:
ST?<CR><LF>
The camera answers:
A complete list of the current settings
Transmit the following to have a command list:
HP?<CR><LF>
The camera answers:
A list with all commands and possible settings
Invalid parameters send to camera: (99 is an invalid parameter)
SH=99<CR><LF>
The camera answers:
02 Bad Parameters!!<CR><LF>
To see firmware number.
VN?<CR><LF>
To see camera ID. It shows the manufacturing lot number.
ID?<CR><LF>
Baud Rate
9600 bps
RS 232C cable
Data Length
8 bit
Start Bit
1 bit
Stop Bit
1 bit
Parity
None
Xon/Xoff Control None
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT
CAMERA
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT
CAMERA