AD-081CL
- 31 -
7.3.5 Pulse Width trigger mode
In this mode, the accumulation time is equal to the trigger pulse width. Here it is possible to
have long exposure times. For the best image quality, the maximum recommended time is <60
frames (2 seconds), however longer exposures may produce acceptable results depending on
the application.
For timing details, refer to fig. 19 through fig. 26 and fig. 29.
To use this mode:
Mode
Setting
Command
Trigger
Pulse Width (PW)
TR1/TR2=2
Output mode
Sync/Separate
IS=0(Sync),IS=1(Separate)
Output Select
8bit, 10bit
OS1/OS2=0 to 4
Scanning
Full/Partial
SC1/SC2 = 0 to 3
Vertical Binning
ON/OFF
BI1/BI2= 0,1
Other functions
Trigger Input
Camera Link / HIROSE 12-pin TI1/TI2=0, 1
Important Note:
1 The minimum width of the trigger is 2L. The minimum interval of trigger input is as
follows.
Output mode:
IS=0 Sync
IS=1 Separate
Smearless OFF In case of Pulse width
>
FVAL(792L)
Exposure time – 792L + 3L
In case of Pulse width(Min:2L)
≦
792L
792L + 2L
Smearless ON
In case of Pulse width
>
FVAL(792L)
Exposure time – 792L + 3L
Incase of Pulse width( Min:199L+2L)
≦
792L
792L + 2L
FVAL(792L) is the FVAL period of continuous operation.
Fig. 32. PW trigger mode (LVAL async) Timing chart