AD-081CL
- 32 -
Fig. 33. PW trigger mode (LVAL sync Details)
Fig. 34. PW trigger mode (LVAL sync) Timing chart
Fig.35. PW trigger mode (LVAL sync details)
In PW mode, when “Smearless ON” is selected, the actual accumulation time is (the trigger
pulse width minus Smearless active period (199L)). If the trigger pulse width is shorter than
199L, the exposure is not active.
Data out Del ay
Del ay of Exposur e St ar t
( Expos ur e)
DATA out
1 to 2L
13 t o 14L
Ext . Tr i g
FVAL
EEN
LVAL
Exposure
Del ay of Exposur e End
XEEN
(Hirose 12pin)
1L = 1420 clock ( 42. 07us)
Pulse Widt h mode( Full Frame) (LVAL aSYNC)
14.2us
32. 1us
Period
1. 5L
Data out Delay
Del ay of Expos ur e St ar t
(Exposure)
DATA out
13. 5L
Ext.Tri g
FVAL
EEN
LVAL
Exposure Period
Pul se Width mode(Ful l Frame (LVAL SYNC)
)
Del ay of Expos ur e End
0. 5 to 1. 5L
XEEN
(Hirose 12pin)
1L = 1420 Clock (42.07us)
t1=0 .5 to 1 .5L