AM-201CL / AB-201CL
- 50 -
Command
Name
Format
Parameter
Remarks
Tap2
PGB2?<CR><LF>
(Data+8192)/ 8192
±
1dB
Pixel Gain for Tap2
8
Pixel Gain RED
Tap3
PGR3=[Param.]<CR><LF>
PGR3?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
(Only AB-201CL)
Pixel Gain for Tap3
9
Pixel Gain Blue
Tap3
PGB3=[Param.]<CR><LF>
PGB3?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
(Only AB-201CL)
Pixel Gain for Tap3
10
Pixel Gain RED
Tap4
PGR4=[Param.]<CR><LF>
PGR4?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
(Only AB-201CL)
Pixel Gain for Tap4
11
Pixel Gain Blue
Tap4
PGB4=[Param.]<CR><LF>
PGB4?<CR><LF>
-891
~
1000
(Data+8192)/ 8192
±
1dB
(Only AB-201CL)
Pixel Gain for Tap4
12
Black level auto
Tap balance
ABA=[Param.]<CR><LF>
0=OFF
1=Once (Run)
2=Continuous
13
Request the
Result of Black
level auto Tap
balance
BBRS?<CR><LF>
0=Complete.
1=Too Bright.
2=Too dark.
3=Timeout Error.
4=Busy.
5=Limit.
6= Trig is not set as
Normal.
14
Fine Black for
tap 2
BL2
=[Param.]<CR><LF>
BL2
?<CR><LF>
-512 to 511
Tap2 Black Fine For
User
15
Fine Black for
tap 3
BL3
=[Param.]<CR><LF>
BL3
?<CR><LF>
-512 to 511
Tap3 Black Fine For
User
16
Fine Black for
tap 4
BL4
=[Param.]<CR><LF>
BL4
?<CR><LF>
-512 to 511
Tap4 Black Fine For
User
17
BayerPixel
FineBlack for
tap 1L-R
BLR1
=[Param.]<CR><LF>
BLR1?<CR><LF>
-512 to 511
Tap1 Black Fine For
User
18
BayerPixel
FineBlack for
tap 1L-B
BLB1
=[Param.]<CR><LF>
BLB1?<CR><LF>
-512 to 511
Tap1 Black Fine For
User
19
BayerPixel
FineBlack for
tap 1R-R
BLR2
=[Param.]<CR><LF>
BLR2?<CR><LF>
-512 to 511
Tap2 Black Fine For
User
20
BayerPixel
FineBlack for
tap 1R-B
BLB2
=[Param.]<CR><LF>
BLB2?<CR><LF>
-512 to 511
Tap2 Black Fine For
User