AM-201CL / AB-201CL
- 31 -
7.5. Normal continuous operation
This is used for applications which do not require triggering. In this mode, the video signal
for the auto-iris lens is available.
For the video timing, refer to the chapters 6.2, 6.3 and 6.4.
The frame rate of full pixels readout is 64.2fps for 2 tap output and 32.2fps for 1 tap
output.
Primary settings to use this mode
Sensor Digitization Taps: SDT= 0 (Two taps) SDT=1 (One tap)
Acquisition Frame Rate:
AR=1
~
42964
Trigger control
Trigger mode: TM=0 (OFF)
Exposure settings
Exposure mode:
EM=1
Exposure time: PE= 10
μ
s
~
2000000
μ
s
or
Select Auto shutter control(ASC)
Exposure time auto:
ASC=1 (ON)
Exposure time auto speed :
ASCS= 1
~
16 (Default is 8)
Exposure time auto max:
ASCEA= 10
~
1048575(
μ
s unit)
Exposure time auto min:
ASCEI= 10
~
1048575 (
μ
s unit)
Note: The AM-201CL and AB-201CL are designed to give priority to the frame rate rather
than the exposure time. If the exposure time is set at a longer time than
15.56ms (1 frame time), the frame rate must be set at a longer time than the
exposure time.
Minimum interval of the image
2 tap output
FULL
2/3 AOI
1/2 AOI
1/4 AOI
1/8 AOI
Minimum frame line
511
415
348
247
196
1 tap output
FULL
2/3 AOI 1/2 AOI 1/4 AOI 1/8 AOI
Minimum frame line
1099
829
694
492
391
Note: The read out area for each AOI is the centered readout (same lines for upper and
lower)