AM-201CL / AB-201CL
- 26 -
6.4. Horizontal timing
6.4.1 If the binning control is 0=OFF or 2=2x1
1LVAL 2260clk = 28.25
μ
s 1clk=12.5ns (via Camera Link)
(Exposure start line 1LVA 2462clk=30.775μs)
Fig.26 Horizontal timing (Vertical binning OFF)
6.4.2 If the binning control is 1=1x2 or 3=2x2
1LVAL 2464clk = 30.8
μ
s 1clk=12.5ns (via Camera Link)
(Exposure Start Line
1LVAL 2868clk=35.85
μ
s)
Fig.27 Horizontal timing (Vertical binning ON)
6.4.3 DVAL output if the Binning control is set to 2=2x1 or 3=2x2
If the Binning control is set to 2=2x1 or 3=2x2, DVAL is output in one pixel period within the
effective output period. Data is output by adding two pixels in horizontally as described
below.
1+2
3+4
5+6
7+8
1913
+ 1914
1915
+1916
1917
+1918
1919
+1920
12.5ns
12.5ns
1920 clk
DATA
DVAL