AM-201CL / AB-201CL
- 48 -
Command
Name
Format
Parameter
Remarks
ASCEI?<CR><LF>
1
7 Pre Dump
TD
=[Param.]<CR><LF>
TD? <CR><LF>
0= Dump off
1=Dump on
G
– Analog control
1 GainAnalog All
GA
=[Param.]<CR><LF>
GA?<CR><LF>
-84 to 672 (AM-201CL)
0 to 672 (AB-201CL)
for AFE 1L, 1R, 2L,
2R
2
FineGain Digital
All
FGA
=[Param.]<CR><LF>
FGA?<CR><LF>
-2393
~
3379
(Data+8192)/ 8192
±
3dB
for AFE 1L, 1R, 2L,
2R
3 Gain Auto
AGC
=[Param.]<CR><LF>
AGC?<CR><LF>
0=OFF
1=Continuous
4
Gain Auto
Reference
AGCF
=[Param.]<CR><LF>
AGCF?<CR><LF>
0 to 8192
5
Gain Auto
speed
AGCS
=[Param.]<CR><LF>
AGCS?<CR><LF>
1 to 16
AGC tracking speed
Setting ,Default=8
6
Gain Auto
Maximum gain
value
AGCGA=[Param.]<CR><L
F>
AGCGA?<CR><LF>
0 to 672 (AM-201CL)
84 to 672 (AB-201CL)
7
Gain Auto
Minimal gain
value
AGCGI=[Param.]<CR><LF
>
AGCGI?<CR><LF>
-84 to 588 (AM-201CL)
0 to 588 (AB-201CL)
8 Black Level
BL
=[Param.]<CR><LF>
BL?<CR><LF>
-1024 to 1023
Digital User Setup
Master
H
– Balance Ratio
1
BalanceRatio
RED
PGR=[Param.]<CR><LF>
PGR?<CR><LF>
-4533
~
17713
(Data+8192)/ 8192
-7
~
+10dB
(Only AB-201CL)
Pixel Gain for WB
2
BalanceRatio
Blue
PGB=[Param.]<CR><LF>
PGB?<CR><LF>
-4533
~
17713
(Data+8192)/ 8192
-7
~
+10dB
(Only AB-201CL)
Pixel Gain for WB
3
Blance White
auto
AWB=[Param.]<CR><LF>
0=OFF
1=Once (Run)
2=Continuous
Only AB-201CL
4
Request the
Result of Blance
white auto
AWRS?<CR><LF>
0=Complete.
1=Too Bright.
2=Too dark.
3=Timeout Error.
4=Busy.
5=Limit.
6= Trig is not set as
Normal.
Only AB-201CL
I
– LUT control