19.3. LEGAL PROTECTIVE ZONE
–
An electrical radiator with insulation class II may be placed in
zone A
. In bathrooms and kitchens
the socket outlet (never a plug contact) has to be placed at a minimum height of 25cm above the
floor. The radiator may never be installed lower than the adapter socket outlet. A fused spare
has to be used outside the room.
–
In
zone B
, an electric radiator of insulation class II may be connected to the electricity grid via a
plug contact that is placed in zone B.
–
The appliance must be mounted and connected by an acknowledge installer in accordance with
the installation instructions and national and currently applicable local regulations.
60 cm
60 cm
60 cm
60 cm
B
A
Fig. 1: Bathroom zone classification
20. TECHNICAL INFORMATION
20.1. GENERAL SPECIFICATIONS
–
Operating voltage: 230V +/-10% 50Hz.
–
Maximum power of 1250W, resistive load.
–
Power supply cable: 800mm, 3 Conductors.
–
Heating standby mode consumption: <0,5W.
–
Electronic PID (Proportional Integral Derivative) control, triggered by a triac.
20.2. SURROUNDINGS
–
IP44 (control panel horizontal oriented after installation).
–
Operating temperature: 0°C to +50°C.
–
Storage temperature: -20°C to +70°C.
–
Comfort temperature setpoint: b7°C and +30°C approximately.
–
Class II, if correctly installed (according to EN60335-1).
–
NTC (negative temperature coefficient) electronic temperature sensor.