15. EXPERT SETTINGS
15.1. ACCESS TO THE EXPERT SETTINGS
Press
for 5 seconds to enter into the programming mode. The cursor moves to ‘setting day and
time’. Press
twice to move to ‘User settings’. Press
for 10 seconds to move to ‘Installer set-
tings’. Press
and
simultaneaously to enter into the ‘Expert settings’
Setting day
and time
Program
settings
User
settings
Installer
settings
Expert
settings
5 sec
10 sec
10 sec
simultaneous
1. Ambient temperature sensor adjustment
2. Setting the power
3. Restoring factory settings
15.2. SETTING SEQUENCE
All settings are consecutive. To exit the Expert settings, press
3 times.
1
2
3
15.2.1. Ambient temperature sensor adjustment
THESE CHANGES SHOULD BE PERFORMED BY QUALIFIED STAFF, IT SHOULD BE PERFORMED
IN PRODUCTION OR ON SITE DURING THE FIRST INSTALLATION.
BEFORE CARRYING OUT THE CALIBRATION IT IS RECOMMENDED TO WAIT FOR 4H AFTER
THE SETING TEMPERATURE MODIFICATION TO INSURE THAT THE AMBIENT TEMPERATURE IS
STABILIZED.
The calibration adjusts the temperature measured by the ambient temperature sensor to compensa-
te for a deviation from + 5°C to - 5°C by intervals of 0.1°C.
1. If the room temperature difference is negative: decrease the temperature measured by the ambi-
ent temperature sensor by pressing
.
–
Example: setting temperature 20°C, ambient temperature 18°C. Difference is -2°C.
If the room temperature difference is positive: increase the temperature measured by the ambient
temperature sensor by pressing
.
–
Example: setting temperature 19°C, ambient temperature 21°C. Difference is +2°C.
2. To validate, save the new value and exit the mode, press
.
1
1